| Frame Material |
Aluminum |
Density is approximately 2,700 kg/m³. Aluminum alloys conduct heat readily, so roof profiles commonly use thermal breaks where energy performance matters. |
Lightweight relative to steel, easy to form into slim profiles, and naturally protected by an oxide layer. Available in a wide range of finishes. |
Thermal bridging can increase heat transfer if profiles are not thermally broken. Deflection, connection design, and finish durability need to be checked for the project conditions. |
Residential extensions, conservatories, and many commercial roofs where low maintenance and relatively slender framing are priorities. |
| Frame Material |
Carbon Steel |
Density is approximately 7,850 kg/m³. Its stiffness and strength allow engineers to design substantial members and long-span structural forms. |
High structural capacity and widely available sections; can be used for large beams, rafters, and trusses. |
Heavier than aluminum and requires suitable corrosion protection. Thermal bridging, fire protection requirements, and connection detailing may affect the design. |
Large-span roofs, atriums, and projects where structural capacity or an exposed industrial-style frame is important. |
| Frame Material |
Stainless Steel |
Density is approximately 8,000 kg/m³. Corrosion resistance varies by grade and exposure; stainless steel also conducts heat, though less readily than aluminum. |
Can provide durable, clean-looking fittings and supports, particularly where corrosion resistance is important. |
Material and fabrication costs are typically higher than those of common carbon steel. Grade selection, surface finish, and compatible connections matter in exposed environments. |
Coastal or demanding environments, exposed fittings, and designs that use slender steel components or visible structural details. |
| Frame Material |
Engineered Timber |
Density varies by species and product; many structural softwoods are roughly 400–700 kg/m³. Timber conducts heat less readily than metal and can be supplied as glulam or other engineered products. |
Warm natural appearance, comparatively low thermal conductivity, and potential suitability for prefabricated structural members. |
Moisture management, drainage, protective coatings, fire design, and connection detailing are essential. Member size and span depend on the timber product and structural design. |
Residential and public spaces where a natural interior finish is desired and the roof can be carefully detailed against moisture. |
| Support System |
Rafter-and-Purlin Framing |
Primary rafters span between supports; purlins or secondary members support the glazing bars or glass panels. |
Familiar construction method with a clear load path and flexible panel layouts. Individual components can often be installed in manageable stages. |
More framing members may be visible. Roof geometry, drainage, glass-panel sizes, and deflection limits must be coordinated. |
Small to medium roofs, pitched glazed roofs, and projects with regular structural bays. |
| Support System |
Truss-Supported Roof |
Triangulated members transfer roof loads to end supports or columns. Trusses may be fabricated from steel, timber, or other engineered materials. |
Can span farther than a simple beam of similar depth and can keep intermediate supports to a minimum. |
Truss depth and connections affect appearance and usable space. Each truss requires project-specific structural design, and glazing must accommodate movement and tolerances. |
Large atriums, entrance canopies, and roofs needing broad clear spans or a visible structural feature. |
| Support System |
Structural Silicone Glazing |
Glass is bonded to a supporting frame using a specifically designed structural silicone system, which may reduce the visibility of external retaining caps. |
Can create a cleaner, more continuous glazed appearance while transferring designed loads through the glazing system. |
Requires compatible glass, silicone, substrates, quality-controlled fabrication, and a system designed for movement and project loads. It is not a substitute for structural engineering. |
Projects seeking a minimal exterior appearance and able to meet the system’s design, testing, and installation requirements. |
| Support System |
Point-Fixed Support |
Glass panels are supported at discrete locations using engineered fittings rather than continuous glazing bars along every edge. |
Can reduce the visual presence of framing and create a highly transparent roof surface. |
Concentrated forces at fixing points require careful glass and connection design. Panel size, edge distances, movement, maintenance access, and water management need attention. |
Architectural feature roofs and canopies where transparency is a priority and specialist structural design is available. |
| Selection Check |
Loads, Glass, and Drainage |
Design should account for applicable local wind, snow, maintenance, and other project loads, as well as glass build-up, roof pitch, and drainage routes. |
Early coordination helps align frame sizing, support spacing, panel dimensions, and performance requirements. |
Final specifications depend on local codes, site exposure, roof geometry, glass safety requirements, condensation control, and the complete engineered system. |
Every project; confirm details with qualified structural and glazing professionals before selecting a final system. |